#!/bin/bash
|
|
|
|
# UCX Information and Testing Script
|
|
# Provides detailed information about UCX configuration and capabilities
|
|
|
|
set -e
|
|
|
|
echo "📋 UCX (Unified Communication X) Information"
|
|
echo "============================================="
|
|
|
|
# Colors for output
|
|
GREEN='\033[0;32m'
|
|
YELLOW='\033[1;33m'
|
|
BLUE='\033[0;34m'
|
|
NC='\033[0m' # No Color
|
|
|
|
print_section() {
|
|
echo -e "\n${BLUE}📌 $1${NC}"
|
|
echo "----------------------------------------"
|
|
}
|
|
|
|
print_info() {
|
|
echo -e "${GREEN}ℹ️ $1${NC}"
|
|
}
|
|
|
|
print_warning() {
|
|
echo -e "${YELLOW}⚠️ $1${NC}"
|
|
}
|
|
|
|
# Function to check UCX installation
|
|
check_ucx_installation() {
|
|
print_section "UCX Installation Status"
|
|
|
|
if command -v ucx_info >/dev/null 2>&1; then
|
|
print_info "UCX tools are installed"
|
|
|
|
# Get UCX version
|
|
if ucx_info -v >/dev/null 2>&1; then
|
|
local version=$(ucx_info -v 2>/dev/null | head -1)
|
|
print_info "Version: $version"
|
|
fi
|
|
else
|
|
print_warning "UCX tools not found"
|
|
echo "Install with: apt-get install ucx-tools libucx-dev"
|
|
return 1
|
|
fi
|
|
|
|
# Check UCX libraries
|
|
local libs_found=0
|
|
for lib in libucp.so libucs.so libuct.so; do
|
|
if ldconfig -p | grep -q "$lib"; then
|
|
libs_found=$((libs_found + 1))
|
|
fi
|
|
done
|
|
|
|
if [ "$libs_found" -eq 3 ]; then
|
|
print_info "All UCX libraries found (ucp, ucs, uct)"
|
|
else
|
|
print_warning "Some UCX libraries may be missing ($libs_found/3 found)"
|
|
fi
|
|
}
|
|
|
|
# Function to show UCX device information
|
|
show_ucx_devices() {
|
|
print_section "UCX Transport Devices"
|
|
|
|
if command -v ucx_info >/dev/null 2>&1; then
|
|
echo "Available UCX transports and devices:"
|
|
ucx_info -d 2>/dev/null || {
|
|
print_warning "Failed to get UCX device information"
|
|
return 1
|
|
}
|
|
else
|
|
print_warning "ucx_info command not available"
|
|
return 1
|
|
fi
|
|
}
|
|
|
|
# Function to show UCX configuration
|
|
show_ucx_config() {
|
|
print_section "UCX Configuration"
|
|
|
|
if command -v ucx_info >/dev/null 2>&1; then
|
|
echo "UCX configuration parameters:"
|
|
ucx_info -c 2>/dev/null | head -20 || {
|
|
print_warning "Failed to get UCX configuration"
|
|
return 1
|
|
}
|
|
|
|
echo ""
|
|
print_info "Key UCX environment variables:"
|
|
echo " UCX_TLS - Transport layers to use"
|
|
echo " UCX_NET_DEVICES - Network devices to use"
|
|
echo " UCX_LOG_LEVEL - Logging level (error, warn, info, debug, trace)"
|
|
echo " UCX_MEMTYPE_CACHE - Memory type caching (y/n)"
|
|
else
|
|
print_warning "ucx_info command not available"
|
|
return 1
|
|
fi
|
|
}
|
|
|
|
# Function to test UCX capabilities
|
|
test_ucx_capabilities() {
|
|
print_section "UCX Capability Testing"
|
|
|
|
if command -v ucx_info >/dev/null 2>&1; then
|
|
print_info "Testing UCX transport capabilities..."
|
|
|
|
# Check for RDMA transports
|
|
local ucx_transports=$(ucx_info -d 2>/dev/null | grep -i "transport\|tl:" || true)
|
|
|
|
if echo "$ucx_transports" | grep -q "rc\|dc\|ud"; then
|
|
print_info "✅ RDMA transports detected (RC/DC/UD)"
|
|
else
|
|
print_warning "No RDMA transports detected"
|
|
fi
|
|
|
|
if echo "$ucx_transports" | grep -q "tcp"; then
|
|
print_info "✅ TCP transport available"
|
|
else
|
|
print_warning "TCP transport not detected"
|
|
fi
|
|
|
|
if echo "$ucx_transports" | grep -q "shm\|posix"; then
|
|
print_info "✅ Shared memory transport available"
|
|
else
|
|
print_warning "Shared memory transport not detected"
|
|
fi
|
|
|
|
# Memory types
|
|
print_info "Testing memory type support..."
|
|
local memory_info=$(ucx_info -d 2>/dev/null | grep -i "memory\|md:" || true)
|
|
if [ -n "$memory_info" ]; then
|
|
echo "$memory_info" | head -5
|
|
fi
|
|
|
|
else
|
|
print_warning "Cannot test UCX capabilities - ucx_info not available"
|
|
return 1
|
|
fi
|
|
}
|
|
|
|
# Function to show recommended UCX settings for RDMA
|
|
show_rdma_settings() {
|
|
print_section "Recommended UCX Settings for RDMA"
|
|
|
|
print_info "For optimal RDMA performance with SeaweedFS:"
|
|
echo ""
|
|
echo "Environment Variables:"
|
|
echo " export UCX_TLS=rc_verbs,ud_verbs,rc_mlx5_dv,dc_mlx5_dv"
|
|
echo " export UCX_NET_DEVICES=all"
|
|
echo " export UCX_LOG_LEVEL=info"
|
|
echo " export UCX_RNDV_SCHEME=put_zcopy"
|
|
echo " export UCX_RNDV_THRESH=8192"
|
|
echo ""
|
|
|
|
print_info "For development/debugging:"
|
|
echo " export UCX_LOG_LEVEL=debug"
|
|
echo " export UCX_LOG_FILE=/tmp/ucx.log"
|
|
echo ""
|
|
|
|
print_info "For Soft-RoCE (RXE) specifically:"
|
|
echo " export UCX_TLS=rc_verbs,ud_verbs"
|
|
echo " export UCX_IB_DEVICE_SPECS=rxe0:1"
|
|
echo ""
|
|
}
|
|
|
|
# Function to test basic UCX functionality
|
|
test_ucx_basic() {
|
|
print_section "Basic UCX Functionality Test"
|
|
|
|
if command -v ucx_hello_world >/dev/null 2>&1; then
|
|
print_info "UCX hello_world test available"
|
|
echo "You can test UCX with:"
|
|
echo " Server: UCX_TLS=tcp ucx_hello_world -l"
|
|
echo " Client: UCX_TLS=tcp ucx_hello_world <server_ip>"
|
|
else
|
|
print_warning "UCX hello_world test not available"
|
|
fi
|
|
|
|
# Check for other UCX test utilities
|
|
local test_tools=0
|
|
for tool in ucx_perftest ucp_hello_world; do
|
|
if command -v "$tool" >/dev/null 2>&1; then
|
|
test_tools=$((test_tools + 1))
|
|
print_info "UCX test tool available: $tool"
|
|
fi
|
|
done
|
|
|
|
if [ "$test_tools" -eq 0 ]; then
|
|
print_warning "No UCX test tools found"
|
|
echo "Consider installing: ucx-tools package"
|
|
fi
|
|
}
|
|
|
|
# Function to generate UCX summary
|
|
generate_summary() {
|
|
print_section "UCX Status Summary"
|
|
|
|
local ucx_ok=0
|
|
local devices_ok=0
|
|
local rdma_ok=0
|
|
|
|
# Check UCX availability
|
|
if command -v ucx_info >/dev/null 2>&1; then
|
|
ucx_ok=1
|
|
fi
|
|
|
|
# Check devices
|
|
if command -v ucx_info >/dev/null 2>&1 && ucx_info -d >/dev/null 2>&1; then
|
|
devices_ok=1
|
|
|
|
# Check for RDMA
|
|
if ucx_info -d 2>/dev/null | grep -q "rc\|dc\|ud"; then
|
|
rdma_ok=1
|
|
fi
|
|
fi
|
|
|
|
echo "📊 UCX Status:"
|
|
[ "$ucx_ok" -eq 1 ] && print_info "✅ UCX Installation: OK" || print_warning "❌ UCX Installation: Missing"
|
|
[ "$devices_ok" -eq 1 ] && print_info "✅ UCX Devices: Detected" || print_warning "❌ UCX Devices: Not detected"
|
|
[ "$rdma_ok" -eq 1 ] && print_info "✅ RDMA Support: Available" || print_warning "⚠️ RDMA Support: Limited/Missing"
|
|
|
|
echo ""
|
|
if [ "$ucx_ok" -eq 1 ] && [ "$devices_ok" -eq 1 ]; then
|
|
print_info "🎉 UCX is ready for SeaweedFS RDMA integration!"
|
|
|
|
if [ "$rdma_ok" -eq 1 ]; then
|
|
print_info "🚀 Real RDMA acceleration is available"
|
|
else
|
|
print_warning "💡 Only TCP/shared memory transports available"
|
|
fi
|
|
else
|
|
print_warning "🔧 UCX setup needs attention for optimal performance"
|
|
fi
|
|
}
|
|
|
|
# Main execution
|
|
main() {
|
|
check_ucx_installation
|
|
echo ""
|
|
|
|
show_ucx_devices
|
|
echo ""
|
|
|
|
show_ucx_config
|
|
echo ""
|
|
|
|
test_ucx_capabilities
|
|
echo ""
|
|
|
|
show_rdma_settings
|
|
echo ""
|
|
|
|
test_ucx_basic
|
|
echo ""
|
|
|
|
generate_summary
|
|
|
|
echo ""
|
|
print_info "For SeaweedFS RDMA engine integration:"
|
|
echo " 1. Use UCX with your Rust engine"
|
|
echo " 2. Configure appropriate transport layers"
|
|
echo " 3. Test with SeaweedFS RDMA sidecar"
|
|
echo " 4. Monitor performance and adjust settings"
|
|
}
|
|
|
|
# Execute main function
|
|
main "$@"
|